Glossary
Signal, software, and application concepts across Radiens, each defined once.
Sections
Filters
Signal
Modality
Practice
117 of 117 terms
Software7
Software platforms, APIs, analysis tools, and applications
- Acquisition Control
Instrument control configures and operates the DAQ hardware; session control is the operator's live operation of a recording.
- Allego
The Radiens acquisition app: instrument control, recording and real-time monitoring of signal quality, with spike sorting and PSTH live.
- NWB (Neurodata Without Borders)
The open standard file format for neurophysiology data; Radiens reads and writes it natively.
- Radiens
The NeuroNexus software platform for electrophysiology: Allego for acquisition, Videre for analysis, RadiensPy and the CLI for scripting; local-first.
- RadiensPy
The free Radiens Python packages: script acquisition in Allego and analysis in Videre from Python and Jupyter, with typed results.
- Trial
In Radiens, one recording: one Record start-to-stop in Allego, saved as one data file. Trial, recording and data file name the same object.
- Videre
The Radiens analysis app: opens any recording in place, plays it back in linked views, and runs spike sorting, PSTH, spectral and field analysis with provenance.
Applications1
Data description, provenance, and workflow concepts across the Radiens platform
- Request for Quote
The purchasing workflow on the NeuroNexus website: configure, add to the quote cart, submit, and an account executive returns pricing and lead time.
Hardware & Neuroscience109
Maintained on neuronexus.com. Each term opens its definition there.
A
- A-Series Packages(opens on neuronexus.com)
Rigid printed-circuit interconnect for acute and intra-operative work; DIP-16, Samtec 40 or Omnetics 32 connectors.
- A-Series Probes (Buzsaki)(opens on neuronexus.com)
Closely spaced sites staggered near the tip of each shank, so one neuron appears on several sites and units separate in sorting.
- A-Series Probes (Isomura)(opens on neuronexus.com)
Shanks and site positions placed to record the same cortical layer across several columns.
- A-Series Probes (Linear and Edge Layouts)(opens on neuronexus.com)
Sites spread along the shank in a linear or edge layout, for laminar and depth profiling.
- A-Series Probes (Polytrode & Tetrode)(opens on neuronexus.com)
Sites in close columns or clusters of four on the shank, for single-unit isolation and current-source density analysis.
- Active-Pixel Probe(opens on neuronexus.com)
A silicon probe with an amplifier under every site, digitized on the probe, so it delivers data instead of one wire per site.
- Activus Package Series(opens on neuronexus.com)
A passive silicon probe with the digitizing chip in the package; micro-HDMI to XDAQ or Smartbox, or Omnetics SPI for Intan.
- Activus SiNAPS Package Series(opens on neuronexus.com)
The package for a SiNAPS probe, with 256 or 1,024 sites digitized on the probe and a Samtec 50-pin connector to the interface box.
- Acute Recording(opens on neuronexus.com)
A preparation in which a probe is inserted for a single recording session and then removed.
- Adapter(opens on neuronexus.com)
Joins a package connector to a headstage input it was not made for, by remapping pins or breaking out a dense connector; the channel map changes.
B
- Brain Coverage Density(opens on neuronexus.com)
The number of electrode sites per cubic millimeter of the tissue volume that a design spans.
- Brain Organoid(opens on neuronexus.com)
A three-dimensional neural tissue grown from human stem cells, with neurons distributed through its volume.
- Bregma(opens on neuronexus.com)
The skull landmark where the coronal and sagittal sutures meet. Stereotaxic coordinates are measured from it.
C
- Cardiac Surface Grid Series(opens on neuronexus.com)
12 µm polyimide grids for the epicardium, with accordion and segmented layouts that hold contact through the cardiac cycle.
- Chronic Recording(opens on neuronexus.com)
A preparation with an implanted probe that records the same region over days to months in an awake animal.
- CM Package Series(opens on neuronexus.com)
Connector mounted on the assembly with no cable; small and light for chronic implants, typically in mice.
- Common Average Reference (CAR)(opens on neuronexus.com)
A re-referencing step that subtracts the average of all channels from each channel to remove signal common to them.
- Commutator(opens on neuronexus.com)
A rotating joint in the tether so a freely moving animal's turns do not wind up the cable.
- Commutators — Standard and PRO(opens on neuronexus.com)
The two X-Series commutators: Standard, passive and mechanical; Commutator PRO, motorized with active torque compensation.
- Connectors — the catalog vocabulary(opens on neuronexus.com)
The connector records every package, adapter and headstage is specified in, so compatibility is answered from the records.
- Cortical Layers(opens on neuronexus.com)
The six layers of the neocortex, numbered I to VI from the surface, which a penetrating probe crosses in order.
- Current Source Density (CSD)(opens on neuronexus.com)
The second spatial derivative of the LFP along a shank, used to estimate where current enters and leaves neurons.
D
- DAQ Chip (Neural Recording ASIC)(opens on neuronexus.com)
The chip in a headstage or probe that amplifies and digitizes electrode signals and sets the channel count and noise floor.
- Data Acquisition System (DAQ)(opens on neuronexus.com)
Acquires the digital data streams from headstages, synchronizes and timestamps them, and streams them to the host computer.
- Data Volume(opens on neuronexus.com)
The size of a recording: channel count times sampling rate times bytes per sample, about 28 GB per hour at 128 channels.
- DBS Package Series(opens on neuronexus.com)
Research DBS array lead with 32 or 40 addressable contacts on a 35 to 60 mm shaft; threaded Omnetics connector.
- DBS Series — rDBSA Research Arrays(opens on neuronexus.com)
Research DBS arrays with the geometry of a clinical lead and 32 or 40 smaller, individually addressable contacts along one shaft.
- Deepest Site(opens on neuronexus.com)
The position of the electrode site nearest the tip of a shank, measured from the tip in millimeters.
- Detection Radius(opens on neuronexus.com)
The distance from an electrode site within which a neuron's spike can be detected, about 50 to 150 µm.
- Drug Delivery Package Series(opens on neuronexus.com)
16-site silicon probe with a fluidic channel on the same shank; DIP-16 or Omnetics 16 connector.
- Drug Delivery Series(opens on neuronexus.com)
A single-shank silicon probe with a stainless-steel fluidic channel beside the array, for infusion and recording at one location.
E
- ECoG Series Thin-Film Grids(opens on neuronexus.com)
12 µm polyimide grids for the cortical surface, epidural or subdural, 4 to 256 platinum sites from 25 µm to 1 mm.
- EIB Package Series(opens on neuronexus.com)
Passive electrode interface board: 64 channels to two Molex 34-pin board-to-board connectors, no active electronics.
- Electrocorticography (ECoG)(opens on neuronexus.com)
Recording of brain activity from the cortical surface, with electrodes placed on the dura or under it.
- Electrode Site(opens on neuronexus.com)
One exposed area of metal on a probe or grid that senses the extracellular voltage and provides one signal channel.
- Electrode Site Span (Width)(opens on neuronexus.com)
The distance between the outermost electrode sites across a probe or grid, perpendicular to the shank.
- Extracellular Recording(opens on neuronexus.com)
Measurement of the voltage that neuronal currents produce in tissue, using an electrode outside the cells.
F
- Filtering (Band-Pass and Notch)(opens on neuronexus.com)
Separating a wide-band recording into spike and field-potential bands, and removing mains interference.
- Firing Rate(opens on neuronexus.com)
The number of spikes a neuron fires per second, estimated over a time window, in time bins, or by smoothing.
- Fusion Double-Sided Silicon Probes(opens on neuronexus.com)
Two catalog probes assembled back to back, with twice the active sites and 360° coverage on each shank.
- Fusion Package Series(opens on neuronexus.com)
Two catalog probes assembled back to back; the doubled site count comes out on several Omnetics connectors.
G
- GPIO (General Purpose I/O)(opens on neuronexus.com)
The analog and digital I/O lines on a DAQ that connect other lab instruments and timestamp their signals with the neural data.
- Grid Electrode (Thin-Film Grid)(opens on neuronexus.com)
A flexible electrode array in a grid layout for a tissue surface, such as an ECoG grid on the cortex or an EEG grid on the skull.
H
- Headstage(opens on neuronexus.com)
Plugs into the package connector and amplifies, filters and digitizes every site at the head; record-only or record-and-stimulate.
- Hippocampus(opens on neuronexus.com)
A layered structure beneath the neocortex, commonly identified in a recording by theta and sharp-wave ripples.
- Hybrid Package Series(opens on neuronexus.com)
A silicon probe on one end of a thin-film ribbon cable, a PCB and connector on the other; probe uncoupled from connector.
I
- Impedance (Electrode Site)(opens on neuronexus.com)
The opposition that an electrode site presents to current, typically stated at 1 kHz. It affects noise and stimulation.
K
- Kontex System Adapter(opens on neuronexus.com)
Adapters into the XDAQ chain: a Neuropixels dock configuration and an XDAQ-side connector remap.
L
- Local Field Potential (LFP)(opens on neuronexus.com)
The extracellular signal below about 100 Hz, produced by many neurons. It is the same signal as ECoG and EEG.
M
- Matrix Array Series(opens on neuronexus.com)
A silicon 3D probe platform of several 2D arrays in slots, most often 32 sites each, with 64 to 256 channels.
- Matrix Package Series(opens on neuronexus.com)
A silicon 3D probe platform of several 2D arrays, most often 32 sites each, at 64 to 256 channels, in passive or Activus builds.
- Michigan Probe(opens on neuronexus.com)
The planar silicon multisite probe developed at the University of Michigan from 1970. NeuroNexus silicon probes descend from it.
- Microdrive(opens on neuronexus.com)
A mount that advances an implanted probe in steps of tens of micrometers, to reach the target or to recover units after the tissue settles.
- Mouse and Rat EEG Grids (EEG Series)(opens on neuronexus.com)
12 µm polyimide EEG arrays for the skull surface, no craniotomy; 6 to 32 sites for mouse and rat.
- Mouse EEG Electrode(opens on neuronexus.com)
Bone-screw electrodes, or a skull-surface thin-film grid of 16 to 32 sites aligned to bregma with no craniotomy.
- MRI-Conditional Package(opens on neuronexus.com)
A package built from non-magnetic parts so a probe records inside the scanner under stated conditions.
N
- Neural Interface Volume(opens on neuronexus.com)
The volume of tissue enclosed by the electrode sites of a design in three dimensions, in cubic millimeters.
- Neural Oscillations(opens on neuronexus.com)
Rhythmic fluctuations in the summed activity of neurons, named by frequency band, that coordinate neuronal firing.
- Neural Probe(opens on neuronexus.com)
An implantable device with precisely positioned electrode sites that record or stimulate neural activity in a targeted region.
- Neuromonitoring (Live Signal Monitoring)(opens on neuronexus.com)
Live observation of a recording as it is acquired, so that site and reference problems are identified during the session.
- NeuroNexus Probe Adapters(opens on neuronexus.com)
Adapters that join a probe package to a headstage or system it was not terminated for, by remapping pins or breaking out a dense connector.
- Neuropixels Probe(opens on neuronexus.com)
imec's CMOS silicon probes that record 384 channels, or 1,536 on the Quad Base, chosen from 960 to 5,120 sites.
O
- Optoelectrode Package(opens on neuronexus.com)
A package build that fixes an optical fiber beside the sites, so light is delivered on the recording trajectory.
P
- PEDOT Site Coating(opens on neuronexus.com)
A conducting-polymer film deposited on electrode sites to lower impedance and increase charge capacity at the same site area.
- Peripheral Nerve Cuff Series(opens on neuronexus.com)
12 µm polyimide cuffs pre-curved at fabrication to wrap a peripheral nerve; diameter chosen, not adjusted.
- Photoelectric Artifact(opens on neuronexus.com)
The voltage transient that a light pulse produces on a metal recording site during optical stimulation.
- Probe Geometry and Site Layouts(opens on neuronexus.com)
The geometry of silicon probe shanks and the layout of electrode sites on them: linear, edge, tetrode, and polytrode.
- Probe Package(opens on neuronexus.com)
The connector assembly built onto an electrode array: interconnect, connector, covering; it fixes headstage, mounting, and weight.
- PSTH and Raster Plot(opens on neuronexus.com)
A raster plot shows a unit's spikes on each trial, aligned to an event. A PSTH shows the trial-averaged firing rate.
Q
- Q-Trode Package Series(opens on neuronexus.com)
One tetrode, four channels, on a CQ4 connector; 0.31 g.
- Q-Trode Series Silicon Probes(opens on neuronexus.com)
Four sites clustered at one depth on a single shank, for single-unit isolation at that depth.
R
- Reference Electrode(opens on neuronexus.com)
The electrode against which every channel is measured. Its placement determines what is subtracted from every channel.
S
- Sampling Rate and Bandwidth(opens on neuronexus.com)
The number of samples per second for each channel. It limits the recorded bandwidth and determines the data volume.
- Shallowest Site(opens on neuronexus.com)
The position of the electrode site nearest the base of a shank, measured from the tip in millimeters.
- Shank Count(opens on neuronexus.com)
The number of penetrating shanks on a silicon probe. Several shanks sample laterally separated tracks in one insertion.
- Shank Length(opens on neuronexus.com)
The tip-to-base length of a silicon probe shank, in millimeters. It limits how deep the sites can be placed.
- Shank Separation(opens on neuronexus.com)
The center-to-center distance between neighboring shanks on a multi-shank silicon probe, in micrometers.
- Signal-to-Noise Ratio (SNR)(opens on neuronexus.com)
A generic metric of signal size relative to noise. For spikes, commonly spike amplitude over the noise on the same channel.
- Silicon Carbide (a-SiC) Dielectric(opens on neuronexus.com)
The proprietary low-stress amorphous silicon carbide NeuroNexus uses as the dielectric (insulating) layer of its silicon probes.
- Silicon Probe(opens on neuronexus.com)
A penetrating neural probe made by thin-film microfabrication on silicon, with electrode sites positioned by photolithography.
- SiNAPS Probe (High-Density Series)(opens on neuronexus.com)
A CMOS active-pixel silicon probe with an amplifier under every site, which records all 256 or 1,024 sites simultaneously.
- SIROF (Sputtered Iridium Oxide Film)(opens on neuronexus.com)
An electrode-site material with low impedance and high charge-injection capacity, for recording and stimulation on silicon probes.
- Site Area(opens on neuronexus.com)
The exposed surface of one electrode site, in square micrometers. With the site material, it sets the site's impedance.
- Site Count(opens on neuronexus.com)
The number of electrode sites on a design, which is the number of channels it can record or stimulate at once.
- Site Density(opens on neuronexus.com)
The number of electrode sites per square millimeter of the site footprint.
- Site Footprint(opens on neuronexus.com)
The area of the rectangle that the electrode sites span, width times depth, in square millimeters.
- Site Pitch(opens on neuronexus.com)
The distance between neighboring electrode sites on a shank, usually measured from site center to site center.
- Site Pitch (Across)(opens on neuronexus.com)
The center-to-center spacing between columns of electrode sites across a shank or over the face of a grid.
- Site Span(opens on neuronexus.com)
The distance along a shank from the first electrode site to the last, which is the length of tissue sampled at once.
- Smartbox Acquisition System(opens on neuronexus.com)
The NeuroNexus data acquisition system, with four ports for Intan-based headstages or one port to the SiNAPS interface box.
- SmartLink Headstages(opens on neuronexus.com)
Plugs straight into the package connector — DIP, Omnetics, ZIF or Samtec — no adapter; 2.0 g, record-only; NeuroNexus-made.
- Spectral Analysis (Spectrogram and Coherence)(opens on neuronexus.com)
Analysis of a field potential by frequency: the power in each band over time, and the coherence between two signals.
- Spike (Extracellular Action Potential)(opens on neuronexus.com)
The extracellular voltage transient produced by one neuron's action potential, recorded by a nearby electrode site.
- Spike Sorting(opens on neuronexus.com)
Grouping the spikes in a recording by waveform similarity so that each group can be attributed to one neuron.
- Spike Train(opens on neuronexus.com)
The sequence of spike times of one unit, from which firing rate, spike timing, and correlation measures are computed.
- Substrate Thickness(opens on neuronexus.com)
The thickness of the silicon or polyimide on which an electrode array is built: 15 or 50 µm silicon, 12 µm polyimide.
T
- The Recording Chain(opens on neuronexus.com)
Site, package, headstage, data acquisition system, software: each chosen separately, each choice constraining the next.
- Thin-Film Electrodes: Silicon Probes and Grids(opens on neuronexus.com)
NeuroNexus thin-film electrodes are of two kinds: silicon probes that penetrate tissue and polyimide grids for surfaces.
- Thin-Film Microfabrication(opens on neuronexus.com)
The process of depositing and patterning thin conductive and insulating layers on a wafer to build a probe or grid.
- Torque Sensing (Commutator)(opens on neuronexus.com)
How the Commutator PRO knows to turn, by a gyroscope that follows the animal's own turn or a Hall sensor that reads the cable's twist at the rotor.
U
- Unit (Single-Unit and Multi-Unit Activity)(opens on neuronexus.com)
A set of spikes grouped by spike sorting and attributed to one source, usually one neuron.
V
- Vector Array Series(opens on neuronexus.com)
Short silicon array on a rigid stainless-steel support body, 16 to 128 sites, for deep targets in large animals.
- Vector Package Series(opens on neuronexus.com)
Vector Array at 16 to 128 channels on a 70 or 110 mm shaft; Omnetics or ZIF-Clip connectors; for deep targets in large animals.
X
- X-Series Adapters(opens on neuronexus.com)
Connector adapters within the X-Series platform: EIB rails, EIB to M1P, X3/X3SR/X6 jumpers and extensions, and the general X-Series connector adapter.
- X-Series Headstages(opens on neuronexus.com)
Digitizes at the head, one micro-HDMI cable, 0.9 to 1.5 g; record-only with accelerometer or stim-record; Kontex-made.
- X-Series Packages(opens on neuronexus.com)
Smallest, lightest package in the catalog; Molex X3 or Panasonic 44-pin connectors that an X-Series headstage mates directly.
- XDAQ Acquisition Systems(opens on neuronexus.com)
The X-Series data acquisition system in three models, engineered and manufactured by Kontex and commercialized by NeuroNexus.
Z
- Z-Coat(opens on neuronexus.com)
The proprietary NeuroNexus PEDOT site coating, with roughly 10× lower impedance and higher charge capacity in the same footprint.
- ZIF Package Series(opens on neuronexus.com)
Hirose zero-insertion-force connectors for TDT ZIF-Clip headstages; 16 to 64 channels.